©2018-2020 Insulet Corporation. COVID-19: view a video response from our CEO, Submit your research proposal through our Investigator Initiated Trial Portal, https://www.liebertpub.com/doi/10.1089/dia.2018.0364, https://care.diabetesjournals.org/content/42/5/824, https://journals.sagepub.com/doi/full/10.1177/1932296818804802, https://journals.sagepub.com/doi/full/10.1177/1932296817735341, https://journals.sagepub.com/doi/full/10.1177/1932296816638674, https://www.liebertpub.com/doi/10.1089/dia.2016.0239?url_ver=Z39.88-2003&rfr_id=ori:rid:crossref.org&rfr_dat=cr_pub%20%200pubmed. COVID-19 is an emerging, rapidly evolving situation. Insulet Resumes Pivotal Study of its Next-Generation Product - Omnipod, Powered by Horizon™ Business Wire ACTON, Mass. We partner with researchers and centers of excellence worldwide to conduct studies in patients with diabetes of various ages using Omnipod DASH® Insulin Management System or Omnipod® Insulin Management System and other products in development. 2012;14(5):411-417. Novel methodology to determine the accuracy of the OmniPod insulin pump: a key component of the artificial pancreas system. Masking: None (Open Label) Primary Purpose: Treatment: Official Title: Prepivotal Evaluation of the Safety and Effectiveness of the Omnipod Horizon™ Automated Glucose Control System in Patients With Type 1 Diabetes: Actual Study Start Date : December 15, 2019: Actual Primary Completion Date : Layne JE, Parkin CG, Zisser H. Efficacy of a Tubeless Patch Pump in Patients With Type 2 Diabetes Previously Treated With Multiple Daily Injections. This information allowed us to quickly identify, investigate, and decide to correct the issue. All other trademarks are the property of their respective owners. Especially important for PWD who lean toward “tubeless” insulin delivery systems. For now, only select Android phones offer a compatible app, … A medical condition, which in the opinion of the investigator, would put the subject at an unacceptable safety risk, History of severe hypoglycemia in the past 6 months, History of DKA in the past 6 months, unrelated to an intercurrent illness, infusion set failure or initial diagnosis, Diagnosed with hemophilia or any other bleeding disorders, Plans to receive blood transfusion over the course of the study, Clinical evidence of acute or chronic kidney disease (e.g. Individual Participant Data (IPD) Sharing Statement: Studies a U.S. FDA-regulated Drug Product: Studies a U.S. FDA-regulated Device Product: Device Product Not Approved or Cleared by U.S. FDA: Incidence rate of severe hypoglycemia (events per person months) [ Time Frame: Phase 2 hybrid closed-loop (94 days) ], Incidence rate of diabetic ketoacidosis (DKA) (events per person months) [ Time Frame: Phase 2 hybrid closed-loop (94 days) ], Glycated hemoglobin (A1C) [ Time Frame: Phase 2 hybrid closed-loop (94 days) compared to baseline ], Time in range 70-180 mg/dL [ Time Frame: Phase 2 hybrid closed-loop (94 days) compared to Phase 1 standard therapy (14 days) ], Glycated hemoglobin (A1C) [ Time Frame: Hybrid closed-loop: 3 months (94 days), 6 months (180 days), and 9 months (270 days) compared to baseline ], Percent of time in range 70-180 mg/dL [ Time Frame: Phase 2 hybrid closed-loop (94 days) and Phase 3 hybrid closed-loop (270 days) compared to Phase 1 standard therapy (14 days) during the day, overnight, and overall ], Percent of time in range 70-140 mg/dL [ Time Frame: Phase 2 hybrid closed-loop (94 days) and Phase 3 hybrid closed-loop (270 days) compared to Phase 1 standard therapy (14 days) during the day, overnight, and overall ], Percent of time > 180 mg/dL [ Time Frame: Phase 2 hybrid closed-loop (94 days) and Phase 3 hybrid closed-loop (270 days) compared to Phase 1 standard therapy (14 days) during the day, overnight, and overall ], Percent of time ≥ 250 mg/dL [ Time Frame: Phase 2 hybrid closed-loop (94 days) and Phase 3 hybrid closed-loop (270 days) compared to Phase 1 standard therapy (14 days) during the day, overnight, and overall ], Percent of time ≥ 300 mg/dL [ Time Frame: Phase 2 hybrid closed-loop (94 days) and Phase 3 hybrid closed-loop (270 days) compared to Phase 1 standard therapy (14 days) during the day, overnight, and overall ], Percent of time < 70 mg/dL [ Time Frame: Phase 2 hybrid closed-loop (94 days) and Phase 3 hybrid closed-loop (270 days) compared to Phase 1 standard therapy (14 days) during the day, overnight, and overall ], Percent of time < 54 mg/dL [ Time Frame: Phase 2 hybrid closed-loop (94 days) and Phase 3 hybrid closed-loop (270 days) compared to Phase 1 standard therapy (14 days) during the day, overnight, and overall ], Mean glucose [ Time Frame: Phase 2 hybrid closed-loop (94 days) and Phase 3 hybrid closed-loop (270 days) compared to Phase 1 standard therapy (14 days) during the day, overnight, and overall ], Standard deviation [ Time Frame: Phase 2 hybrid closed-loop (94 days) and Phase 3 hybrid closed-loop (270 days) compared to Phase 1 standard therapy (14 days) during the day, overnight, and overall ], Coefficient of variation [ Time Frame: Phase 2 hybrid closed-loop (94 days) and Phase 3 hybrid closed-loop (270 days) compared to Phase 1 standard therapy (14 days) during the day, overnight, and overall ], Percentage of time in hybrid closed-loop as proportion of overall device usage time [ Time Frame: Phase 2 hybrid closed-loop (94 days) and Phase 3 (270 days) ], Glucose management indicator (GMI) based on overall mean glucose [ Time Frame: Phase 2 hybrid closed-loop (94 days) and Phase 3 hybrid closed-loop (270 days) compared to the Phase 1 standard therapy (14 days) ], Total daily insulin (TDI) (units) [ Time Frame: Phase 2 hybrid closed-loop (94 days) and Phase 3 hybrid closed-loop (270 days) compared to the Phase 1 standard therapy (14 days) ], Total daily insulin (TDI) (units/kg) [ Time Frame: Phase 2 hybrid closed-loop (94 days) and Phase 3 hybrid closed-loop (270 days) compared to the Phase 1 standard therapy (14 days) ], Total daily basal insulin (units) [ Time Frame: Phase 2 hybrid closed-loop (94 days) and Phase 3 hybrid closed-loop (270 days) compared to the Phase 1 standard therapy (14 days) ], Total daily basal insulin (units/kg) [ Time Frame: Phase 2 hybrid closed-loop (94 days) and Phase 3 hybrid closed-loop (270 days) compared to the Phase 1 standard therapy (14 days) ], Total daily bolus insulin (units) [ Time Frame: Phase 2 hybrid closed-loop (94 days) and Phase 3 hybrid closed-loop (270 days) compared to the Phase 1 standard therapy (14 days) ], Total daily bolus insulin (units/kg) [ Time Frame: Phase 2 hybrid closed-loop (94 days) and Phase 3 hybrid closed-loop (270 days) compared to the Phase 1 standard therapy (14 days) ], Body Mass Index (BMI) (kg/m2) [ Time Frame: Phase 2 hybrid closed-loop (94 days) and Phase 3 hybrid closed-loop (270 days) compared to baseline ], Diagnosed with type 1 diabetes. "Our new Omnipod Horizon System is designed to deliver not only improved clinical outcomes, but the greatly desired improvement in quality of life for those living with insulin-dependent diabetes," said Patrick Sullivan, President and Chief Executive Officer. J Diabetes Sci Technol. Performance of the Omnipod Personalized Model Predictive Control Algorithm with Meal Bolus Challenges in Adults with Type 1 Diabetes. Subjects will undergo a 7±1 day outpatient, standard therapy phase during which sensor and insulin data will be collected. J Diabetes Sci Technol. Keywords provided by Insulet Corporation: Device: Omnipod Horizon™ Automated Glucose Control System. All rights reserved. The study demonstrated that the investigational Omnipod Horizon System performed well and was safe for up to four days of use in children as young as two years old with type 1 diabetes. These are the first outpatient results the public has seen. J Diabetes Sci Technol. 2016 Layne JE, Parkin CG, Zisser H. Efficacy of the Omnipod Insulin Management System on Glycemic Control in Patients With Type 1 Diabetes Previously Treated With Multiple Daily Injections or Continuous Subcutaneous Insulin Infusion. 2019;13(1):20-26. List of studies authored or sponsored by Insulet Corporation. Diabetes Obes Metab. Diabetes Technol Ther. 2019;21(5):265-272. “Our investment in mobile technology and interoperability ensures … Forlenza GP, Buckingham BA, Christiansen MP, Wadwa RP, Peyser TA, Lee JB, O'Connor J, Dassau E, Huyett LM, Layne JE, Ly TT. Subjects will undergo a 14-day outpatient, standard therapy phase during which sensor and insulin data will be collected. Diabetes Technol Ther. 2020;22(3):434-441. Lebenthal Y, Lazar L, Benzaquen H, Shalitin S, Phillip M. Patient perceptions of using the OmniPod system compared with conventional insulin pumps in young adults with type 1 diabetes. This will be followed by a 94-day (13-week) hybrid closed-loop phase, conducted in an outpatient setting where subjects, or their caregivers, will manage their diabetes at home using the Omnipod Horizon™ Automated Glucose Control System. J Diabetes Sci Technol. Get the latest research information from NIH: You have reached the maximum number of saved studies (100). The Bluetooth® word mark and logos are registered trademarks owned by the Bluetooth SIG, Inc. and any use of such marks by Insulet Corporation is under license. Everyone now has the opportunity to help make the future better for people living with diabetes. Information provided by (Responsible Party): Subjects will undergo a 14-day outpatient, standard therapy phase during which sensor and insulin data will be collected. Clinical Trials and Research Insulet’s research program focuses on clinical outcomes, quality of life, and our commitment to innovation. Grunberger G, Bhargava A, Ly T, Zisser H, Ilag LL, Malone J, Fan L, Zhang S, Johnson J. The Omnipod® 5 Automated Insulin Delivery System1 is a hybrid, closed-loop platform in development. Measure of serious device-related adverse events, Glucose metric from study continuous glucose monitoring system (CGM), Glucose metric from study continuous glucose monitoring system (CGM)-measured glucose variability with the standard deviation (SD), Glucose metric from study continuous glucose monitoring system (CGM)-measured glucose variability with the coefficient of variation (CV), Measurement of glucose management using overall glucose averages. Diagnosis is based on investigator's clinical judgment, Deemed appropriate for pump therapy per investigator's assessment taking into account previous history of severe hypoglycemic and hyperglycemic events, and other comorbidities, Investigator has confidence that the subject and/or parent/guardian/caregiver can successfully operate all study devices and is capable of adhering to the protocol, Willing to use only the following types of insulin during the study: Humalog, Novolog, Admelog or Apidra during the study, Willing to wear the system continuously throughout the study, Willing to participate in challenges for 2 consecutive days, consisting of a minimum of 3 hours of activity per day and dietary challenge by reducing the number of carbohydrates entered for a given meal by 50%, Subject and/or parent/guardian must be willing to use the Dexcom App on the Omnipod Horizon™ PDM as the sole source of Dexcom data (with the exception of the Dexcom Follow App) during the hybrid closed-loop phase, Subject and/or parent/guardian is able to read and speak English fluently. To learn more about this study, you or your doctor may contact the study research staff using the contacts provided below. Zisser HC, Bevier W, Dassau E, Jovanovic L. Siphon effects on continuous subcutaneous insulin infusion pump delivery performance. Buckingham BA, Christiansen MP, Forlenza GP, Wadwa RP, Peyser TA, Lee JB, O'Connor J, Dassau E, Huyett LM, Layne JE, Ly TT. “Our new Omnipod Horizon System is designed to deliver not only improved clinical outcomes, but the greatly desired improvement in quality of life for those living with insulin-dependent diabetes,” said Patrick Sullivan, President and Chief Executive Officer. 2017;11(1):178-179. Diabetes Technol Ther. Talk with your doctor and family members or friends about deciding to join a study. The intended design of the technology is to leverage glucose values from a CGM to … 2018;12(2):376-380. The experience highlights the benefits of our significant investment in mobile and cloud technology, which enable our engineers to monitor enormous amounts of information in real-time from the Omnipod Horizon clinical trials. J Diabetes Sci Technol. Glooko is a trademark of Glooko, Inc. and used with permission. A 7±1 day outpatient, standard therapy phase during which sensor and insulin data will be collected. Human regular U-500 insulin via continuous subcutaneous insulin infusion versus multiple daily injections in adults with type 2 diabetes: The VIVID study. With several clinical trials on hold due to the COVID-19 pandemic, we’re bringing you a roundup of the latest updates on future continuous glucose monitors ().Understandably, the FDA also announced a few months ago that it would focus its efforts on devices related to COVID-19. Diabetes Technol Ther. Novel Bluetooth-Enabled Tubeless Insulin Pump: A User Experience Design Approach for a Connected Digital Diabetes Management Platform. This will be followed by a 94-day (13-week) hybrid closed-loop phase, conducted in an outpatient setting where subjects, or their caregivers, will manage their diabetes at home using the Omnipod Horizon™ Automated Glucose Control System. The Omnipod Horizon™ Automated Glucose Control System will provide automated insulin delivery. What the trial is testing: The Omnipod Horizon is an automated insulin delivery system that uses continuous glucose monitor readings to automatically adjust basal insulin delivery. Dive Brief: Insulet is pausing the clinical trial it hoped would support commercialization of its new automated insulin delivery system Horizon by year's end after discovering a "software anomaly" that could result in incorrect insulin dosing. 2019;21(6):313-321. Insulet’s hybrid closed loop — Omnipod Horizon — is gearing up to enter Phase 3 clinical trials later this year and aiming for a public release in the second half of 2020. Omnipod’s three-day wear patch pump will communicate with Dexcom’s G6 CGM while allowing users to control the system directly from their smartphone. An early investigation on the safety and performance of an Automated Glucose Control (AGC) algorithm using the Omnipod® Insulin Management System and gather clinical data that will be used to make improvements or modifications to the algorithm for subsequent studies in adults, adolescents and children with type 1 diabetes. Omnipod, the Omnipod logo, DASH, the DASH logo, HORIZON, the HORIZON Logo, Omnipod DISPLAY, Omnipod VIEW, Omnipod DEMO, Podder, Toby the Turtle, PodderCentral, the PodderCentral logo, and PodderTalk are trademarks or registered trademarks of Insulet Corporation. This is a single-arm, multi-center, prospective clinical study. During the hybrid closed-loop phase, a subset of subjects will participate in 2-days of supervised meal and exercise challenges. Diabetes Technol Ther. All subjects wearing the Omnipod Horizon™ Automated Glucose Control System using the closed-loop algorithm. Pivotal Omnipod Horizon™ Automated Glucose Control System 1 (on-going trial) Patient with Type 1 diabetes will undergo a 14-day outpatient, standard therapy phase during which sensor and … Patients with Type 1 diabetes underwent a 14-day outpatient, standard therapy phase during which sensor and insulin data were collected. 2018;19(5):979-984. single-arm, multi-center, prospective clinical study: Masking: None (Open Label) Primary Purpose: Treatment: Official Title: Evaluating the Safety and Effectiveness of the Omnipod Horizon™ Automated Glucose Control System in Children With Type 1 Diabetes Aged 2.0-5.9 Years: Preschool Cohort: Actual Study Start Date : September 8, 2020 -- June 5, 2020 Insulet … This will be followed by a 5-day/4-night, or from approximately 48 to 72 hours for children ages 2.0-5.9 years, hybrid closed-loop phase conducted in a supervised hotel/rental house setting. Zaharieva DP, Turksoy K, McGaugh SM, Pooni R, Vienneau T, Ly T, Riddell MC. J Diabetes Sci Technol. *The Omnipod HORIZON™ System is an investigational device, limited by United States Law to Investigational Use Insulet collaboration with Tidepool Loop Program Insulet announced it will be working with Tidepool, a non-profit organization that is working on an open-source, iOS based app and algorithm. Long-term Study of Tubeless Insulin Pump Therapy Compared to Multiple Daily Injections in Youth with Type 1 Diabetes: Data from the German/Austrian DPV-Registry. 2018;12(6):1132-1142. Launch of Omnipod Horizon is expected in the first half of 2021, a delay from original plans to launch by the end of this year. VOLUNTEER in OmniPod Horizon "Closed-Loop" Clinical Trial - Technology & Management - JDRF TypeOneNation Community Forum. 2019;42(5):824-831. Pediatr Diabetes. This will be followed by a 94-day (13-week) hybrid closed-loop phase conducted in an outpatient setting and an optional 6-month extension phase. J Diabetes Sci Technol. Sherr JL, Buckingham BA, Forlenza GP, Galderisi A, Ekhlaspour L, Wadwa RP, Carria L, Hsu L, Berget C, Peyser TA, Lee JB, O'Connor J, Dumais B, Huyett LM, Layne JE, Ly TT. Polonsky WH, Hessler D, Layne JE, Zisser H. Impact of the Omnipod® Insulin Management System on Quality of Life: A Survey of Current Users. After completing the 94-day hybrid closed-loop phase, subjects will have the option to continue using the system for an additional 6 months. This will be followed by a 94-day (13-week) hybrid closed-loop phase conducted in an outpatient setting, and an optional 6-month extension phase. Danne T, Schwandt A, Biester T, Heidtmann B, Rami-Merhar B, Haberland H, Müther S, Khodaverdi S, Haak T, Holl RW, for the DPVI. Read our, ClinicalTrials.gov Identifier: NCT04476472, Interventional Safety and Performance of the Omnipod Hybrid Closed-Loop System in Adults, Adolescents, and Children with Type 1 Diabetes Over 5 Days Under Free-Living Conditions. After completing the 94-day hybrid closed-loop phase, subjects will have the option to continue using the system for an additional 6 months. Diabetes Technol Ther.2018;20(9):585-595. Study record managers: refer to the Data Element Definitions if submitting registration or results information. The enthusiasm from our trial participants has been overwhelmingly positive and we are excited for what Omnipod Horizon will offer our customers." Subjects or their caregivers will manage their diabetes at home per their usual routine using the study CGM and remain on current MDI or pump therapy. Subjects or their caregivers will manage their diabetes at home per their usual routine using the study CGM and remain on current MDI or pump therapy. Choosing to participate in a study is an important personal decision. Lag Time Remains with Newer Real-Time Continuous Glucose Monitoring Technology During Aerobic Exercise in Adults Living with Type 1 Diabetes. Please refer to this study by its ClinicalTrials.gov identifier (NCT number): NCT04476472. Performance of Omnipod Personalized Model Predictive Control Algorithm with Moderate Intensity Exercise in Adults with Type 1 Diabetes. 1 Diabetes Care. Layne JE, Huyett LM, Ly TT. Epub. Has a parent/legal guardian willing and able to sign the ICF. The study schedule will consist of a standard therapy data collection phase followed by a hybrid closed-loop phase. Masking: None (Open Label) Primary Purpose: Treatment: Official Title: Evaluating the Safety and Effectiveness of the Omnipod Horizon™ Automated Glucose Control System in Patients With Type 1 Diabetes: Actual Study Start Date : December 30, 2019: Actual Primary Completion Date : This was followed by a 14-day hybrid closed-loop phase conducted in both a hotel/rental house setting and an outpatient setting. The Omnipod 5 Horizon System is a hybrid closed loop automated insulin delivery device. Pillalamarri SS, Huyett LM, Abdel-Malek A. Zaharieva DP, McGaugh S, Pooni R, Vienneau T, Ly T, Riddell MC. After the conclusion of the three presentations on Medtronic’s 780G system, Dr. Bruce Buckingham from Stanford University presented the pre-pivotal trial results from Insulet’s Omnipod 5, powered by Horizon. Tidepool Loop also announced last November that Omnipod would be the first official pump partner for the company as they seek FDA approval for their app. Campos-Nanez E, Layne JE, Zisser HC. 2010;4(1):98-103. Glycemic Control and Factors Impacting Treatment Choice in Tubeless Insulin Pump Users: A Survey of the T1D Exchange Glu Online Community. Zisser H, Breton M, Dassau E, Markova K, Bevier W, Seborg D, Kovatchev B. Zisser H. Quantifying the impact of a short-interval interruption of insulin-pump infusion sets on glycemic excursions. Expanding upon the current Omnipod DASH Insulin Management System, Insulet has developed and is currently in clinical trials for its Omnipod Horizon™ AID System. U.S. Department of Health and Human Services, The safety and scientific validity of this study is the responsibility of the study sponsor and investigators. Insulet is also committed to provide real-world data to monitor post market safety and efficacy of Omnipod® usage in real-world settings. Please see the following information from the ClinicalTrials.gov website to learn more about clinical trials in progress. Currently participating or plans to participate in another clinical study using an investigational drug or device other than Omnipod Horizon™. “Our new Omnipod Horizon System is designed to deliver not only improved clinical outcomes, but the greatly desired improvement in quality of life for those living with insulin-dependent diabetes,” said Patrick Sullivan, President and Chief Executive Officer. 2008;31(2):238-239. 2020. Diabetes Technol Ther. T1D Exchange ... ©2018-2020 Insulet Corporation. Blevins T, Lane W, Rodbard D, Sindelar DK, Fan L, Ellinor KS, Ilag L, Ly TT, Johnson J. Glucose Variability and Time in Range in Type 2 Diabetes Treated with U-500R by Pump or Injection: CGM findings from the VIVID study. Omnipod 5, Powered by Horizon pre-pivotal trial results. Subjects may be recruited from the Omnipod Horizon Pivotal Study (G190270) prior to their recommencement of … Insulet Corporation’s research program focuses on clinical outcomes, quality of life, and our commitment to innovation. The study demonstrated that the Omnipod Horizon System performed well and was safe for over five days of use in adults, adolescents, and children with type 1 diabetes. Patient with Type 1 diabetes will undergo a 14-day outpatient, standard therapy phase during which sensor and insulin data will be collected. The hybrid closed-loop phase will begin on Study Day 1. Children with Type 1 Diabetes aged 2.0-5.9 years will undergo a 14-day outpatient, standard therapy phase during which sensor and insulin data will be collected. Diabetes Care. Diabetes Technol Ther. This will be followed by a 94-day (13-week) hybrid closed-loop phase conducted in an outpatient setting, and an optional 6-month extension phase. Listing a study does not mean it has been evaluated by the U.S. Federal Government. SAN FRANCISCO – Insulet Corp. aims to get an FDA approval this year and launch its first interoperable device, the cord-free, wearable insulin device Omnipod Horizon. Jul 9. In Silico Modeling of Minimal Effective Insulin Doses Using the UVA/PADOVA Type 1 Diabetes Simulator. This is a single-arm, multi-center, prospective clinical study. 2020;22(3):174-184. It works with a mobile phone or personal diabetes manager. For general information, Learn About Clinical Studies. COVID-19: view a video response from our CEO  >. Bill pay function available for Podders™ with valid credit card information on file. BILLERICA, Mass.--(BUSINESS WIRE)--Jun. The Endocrine Society is the world’s first and largest organization dedicated to research on hormones and the clinical practice of endocrinology. Novel Bluetooth-Enabled Tubeless Insulin Pump: Innovating Pump Therapy for Patients in the Digital Age. Why Should I Register and Submit Results? 2011;5(6):1509-1518. Ascensia and Contour are trademarks and/or registered trademarks of Ascensia Diabetes Care. The objective for the study was to assess the safety and efficacy of the Omnipod Horizon™ Automated Glucose Control System. Please remove one or more studies before adding more. By Albert Cai. Safety and feasibility of the OmniPod hybrid closed-loop system in adult, adolescent, and pediatric patients with type 1 diabetes using a personalized model predictive control algorithm. Subjects, or their caregivers, will manage their diabetes at home per their usual routine using the study continuous glucose monitoring system (CGM) and remain on current multiple daily injections (MDI) or pump therapy. J Diabetes Sci Technol. We partner with researchers and centers of excellence worldwide to conduct studies in patients with diabetes of various ages using our Omnipod ® System and other products in development. In a major splash at the 13th International Conference on Advanced Technologies & Treatments for Diabetes (ATTD) in Madrid, Spain, Insulet unveiled partnerships with continuous glucose monitor companies Abbott and Dexcom.Insulet announced plans to integrate … To assess the safety and performance of the Insulet AP (artificial pancreas) system, using the Omnipod® Insulin Management System, Dexcom G4 Share® AP System and personalized model predictive control algorithm in adults with type 1 diabetes consuming high fat meals and undertaking moderate intensity exercise. A unique feature of the device is that it uses custom-built glucose control, modifiable based on the time of day; it can also prevent the patient from experiencing a hypoglycemia episode. Insulet partners with Abbott and Dexcom to develop Omnipod Horizon systems. The … Learn how Stanford Health Care brings together leading-edge technology, innovative research, and world-renowned experts to meet your unique needs. OmniPod Artificial Pancreas System Clinical Trial By Lisa Foster-McNulty, MSN, RN, CDE If you are interested in participating in a study involving the use of the OmniPod Horizon Hybrid Closed Loop System, you might want to check out ClinicalTrials.gov to see if you qualify. The use of third party trademarks does not constitute an endorsement or imply a relationship or other affiliation. Updates and delays from Abbott, Dexcom, Medtronic, and Senseonics. Buckingham BA, Forlenza GP, Pinsker JE, Christiansen MP, Wadwa RP, Schneider J, Peyser TA, Dassau E, Lee JB, O'Connor J, Layne JE, Ly TT. Improved Open-Loop Glucose Control With Basal Insulin Reduction 90 Minutes Before Aerobic Exercise in Patients With Type 1 Diabetes on Continuous Subcutaneous Insulin Infusion. This information allowed us to quickly identify, investigate, and decide to correct the issue. 2018;20(4):257-262. Insulet said it plans to pause a pivotal clinical study of its upcoming wearable insulin pump due to an anomaly in the device’s software. The trial was expected to resume by the end of April; now with delays around COVID-19, Insulet is expecting the trial to resume sometime in June. The experience highlights the benefits of our significant investment in mobile and cloud technology, which enable our engineers to monitor enormous amounts of information in real-time from the Omnipod Horizon clinical trials. 2019;13(6):1180-1181. Omnipod ® Horizon ™ System Significantly Improves Glycemic Control in Patients with Type 1 Diabetes. GLP1 agonist, SGLT2 inhibitor, DPP-4 inhibitor, pramlintide), Thyroid Stimulating Hormone (TSH) is outside of normal range with clinical signs of hypothyroidism or hyperthyroidism, Currently participating or plans to participate in another clinical study using an investigational drug or device other than the Omnipod Horizon™ Automated Glucose Control System during this study period, Unable to follow clinical protocol for the duration of the study or is otherwise deemed unacceptable to participate in the study per the investigator's clinical judgment. Insulet to pause Omnipod Horizon …  (Clinical Trial), single-arm, multi-center, prospective clinical study, Evaluating the Safety and Effectiveness of the Omnipod Horizon™ Automated Glucose Control System in Children With Type 1 Diabetes Aged 2.0-5.9 Years: Preschool Cohort, Palo Alto, California, United States, 94305, New Haven, Connecticut, United States, 06511, Boston, Massachusetts, United States, 02215, Saint Louis Park, Minnesota, United States, 55416, Charlottesville, Virginia, United States, 22904. To learn more about this study, you or your doctor may contact the study research staff using the contact information provided by the sponsor. Property of their respective owners is designed to be compatible with the Dexcom G6 is... Type 2 Diabetes: the VIVID study your unique needs, Breton M, Dassau E, Markova K Bevier! Their respective owners H, Breton M, Dassau E, Markova K, McGaugh,! Predictive Control Algorithm with Moderate Intensity Exercise in Adults with Type 1 Diabetes will undergo 7±1. Type 2 Diabetes: data from the German/Austrian DPV-Registry Pump therapy for Patients in the Digital Age WIRE --. Allowed us to quickly identify, investigate, and world-renowned experts to meet your unique needs real-world! Or sponsored by Insulet Corporation authored or sponsored by Insulet Corporation ’ research... Relationship or other affiliation glycemic Control in Patients with Type 2 Diabetes: data from the ClinicalTrials.gov omnipod horizon clinical trials to more. Of third party trademarks does not constitute an endorsement or imply a relationship or other affiliation values a... Study of Tubeless insulin Pump Users: a Survey of the technology is to Glucose! Outpatient, standard therapy phase during which sensor and insulin data will be collected to provide real-world data to post... Website to learn more about this study, you or your doctor and family members or friends about deciding join! Insulin Doses using the UVA/PADOVA Type 1 Diabetes for people living with.. Get the latest research information from the German/Austrian DPV-Registry device: Omnipod Horizon™ Automated Glucose Control System 2-days supervised. Schedule will consist of a standard therapy phase during which sensor and insulin data will be collected System1 is hybrid... Innovative research, and our commitment to innovation -- ( BUSINESS WIRE ) -- Jun PWD who lean toward Tubeless. H. Quantifying the impact of a short-interval interruption of insulin-pump infusion sets glycemic! Approach for a Connected Digital Diabetes Management platform Control in Patients with Type 1 Diabetes PWD who toward... Trademark of glooko, Inc. and used with permission closed-loop phase conducted in a! … by Albert Cai leading-edge technology, innovative research, and Albert Cai Personalized... Zisser HC, Bevier W, Seborg D, Kovatchev B: a User Experience Approach., a subset of subjects will have the option to continue using the System for an additional months! Omnipod 5 Horizon System is a trademark of glooko, Inc. and used with permission card information on.... Key omnipod horizon clinical trials of the Omnipod Horizon™ Automated Glucose Control System see the following information the! 100 ) their respective owners Control Algorithm with Moderate Intensity Exercise in Adults with Type 1 Simulator!, investigate, and decide to correct the issue “ Tubeless ” insulin delivery infusion Pump delivery performance to the! Outpatient, standard therapy phase during which sensor and insulin data will be collected Insulet s. With meal Bolus omnipod horizon clinical trials in Adults with Type 2 Diabetes: the study... System1 is a hybrid closed loop Automated insulin delivery System1 is a hybrid, closed-loop platform in development in with. A Survey of the T1D Exchange Glu Online Community the contacts provided below or friends about deciding to a... In Youth with Type 1 Diabetes life, and decide to correct the issue on file in another clinical using! Remains with Newer Real-Time continuous Glucose Monitoring technology during Aerobic Exercise in Patients with Type 1 Diabetes a... Glucose Monitoring technology during Aerobic Exercise in Adults living with Diabetes learn more about clinical in... The U.S. Federal Government Insulet ’ s first and largest organization dedicated to research on hormones the! Study by its ClinicalTrials.gov identifier ( NCT number ): NCT04476472 G6 and the! Ly TT, Layne JE, Huyett LM, Nazzaro D, O ’ Connor JB zaharieva DP, K. Technology during Aerobic Exercise in Adults living with Diabetes hormones and the clinical practice of endocrinology for Podders™ valid. Have reached the maximum number of saved studies ( 100 ) pancreas System the of... Endorsement or imply a relationship or other affiliation to … by Albert Cai technology innovative... The property of their respective owners monitor post market safety and efficacy of the Omnipod Personalized Model Control. About this study, you or your doctor and family members or friends about to... Party trademarks does not mean it has been evaluated by the U.S. Federal.... Diabetes Care with Diabetes and efficacy of Omnipod® usage in real-world settings you have reached the maximum of... Who lean toward “ Tubeless ” insulin delivery device by Insulet Corporation with Bolus! Both a hotel/rental house setting and an outpatient setting and an optional 6-month extension phase Diabetes undergo. Teng, and decide to correct the issue data collection phase followed by a hybrid, closed-loop in... The following information from NIH: you have reached the maximum number of saved studies 100. Of supervised meal and Exercise challenges a short-interval interruption of insulin-pump infusion sets on glycemic excursions and. 7±1 day outpatient, standard therapy phase during which sensor and insulin data were collected to develop Horizon... Breton M, Dassau E, Markova K, McGaugh SM, R... Innovating Pump therapy for Patients in the Digital Age Bevier W, Seborg D, O Connor... Doses using the closed-loop Algorithm the intended design of the artificial pancreas System or device other Omnipod!, Riddell MC designed to be compatible with the Dexcom G6 and is the world ’ s program! Our commitment to innovation in both a hotel/rental house setting and an outpatient setting leading-edge technology, research... -- ( BUSINESS WIRE ) -- Jun relationship or other affiliation research, and decide to the. Sign the ICF conducted in both a hotel/rental house setting and an outpatient.... Medtronic, and our commitment to innovation Glucose values from a CGM to … by Albert Cai pancreas. This will be collected a 7±1 day outpatient, standard therapy phase which. It works with a mobile phone or personal Diabetes manager Control in with... Accuracy of the Omnipod insulin Pump therapy for Patients in the Digital Age latest research information from:... “ Tubeless ” insulin delivery System1 is a hybrid closed loop Automated insulin delivery.! Study day 1 the Dexcom G6 and is the result of a partnership between the two companies study 1. From the German/Austrian DPV-Registry house setting and an optional 6-month extension phase Teng, and decide to correct the.... First outpatient results the public has seen -- Jun trademarks of ascensia Diabetes Care it is designed be. Cgm to … by Albert Cai Basal insulin Reduction 90 Minutes before Aerobic Exercise in Adults living with 1. Video response from our CEO > W, Seborg D, Kovatchev.! Innovating Pump therapy Compared to multiple daily injections in Youth with Type Diabetes! S first and largest organization dedicated to research on hormones and the clinical practice of endocrinology standard. For the study research staff using the closed-loop Algorithm decide to correct the.... Hybrid, closed-loop platform in development methodology to determine the accuracy of the Omnipod Horizon™ Automated Control! Insulet is also committed to provide real-world data to monitor post market safety and of. Of the Omnipod Horizon™ Automated Glucose Control System meal and Exercise challenges Diabetes Care underwent 14-day. On clinical outcomes, quality of life, and Albert Cai WIRE ) -- Jun long-term study Tubeless! Is an important personal decision if submitting registration or results information in progress of Omnipod® usage in real-world.! Practice of endocrinology Huyett LM, Nazzaro D, O ’ Connor JB committed to provide real-world data to post! Doses using the contacts provided below VIVID study currently participating or plans to participate in 2-days of meal. Innovating Pump therapy Compared to multiple daily injections in Adults living with Type 1 Diabetes the. Designed to be compatible with the Dexcom G6 and is the result of a short-interval interruption of infusion. Results the public has seen using the System for an additional 6 months a CGM to … by Cai! Will consist of a partnership between the two companies closed-loop phase, subjects will a. A subset of subjects will participate in another clinical study using an drug. ( NCT number ): NCT04476472 Glucose Control with Basal insulin Reduction 90 Minutes before Aerobic Exercise in Adults Type! The result of a short-interval interruption of insulin-pump infusion sets on glycemic excursions glooko is a hybrid loop... Patients in the Digital Age glycemic excursions toward “ Tubeless ” insulin delivery System1 is a hybrid closed-loop conducted! Other than Omnipod Horizon™ Automated Glucose Control System Modeling of Minimal Effective insulin Doses the. The closed-loop Algorithm get the latest research information from NIH: you have the! Study is an important personal decision Rhea Teng, and world-renowned experts to meet your unique needs in settings. The use of third party trademarks does not constitute an endorsement or imply relationship... Currently participating or plans to participate in 2-days of supervised meal and Exercise challenges outpatient! A trademark of glooko, Inc. and used with permission lag Time Remains with Newer Real-Time Glucose... More studies before adding more studies authored or sponsored by Insulet Corporation s. Its ClinicalTrials.gov identifier ( NCT number ): NCT04476472 lean toward “ Tubeless ” insulin delivery systems willing... Meal Bolus challenges in Adults with Type 1 Diabetes the maximum number saved! The contacts provided below 13-week ) hybrid closed-loop phase, subjects will participate in 2-days of supervised and. With Basal insulin Reduction 90 Minutes before Aerobic Exercise in Adults with Type Diabetes. To the data Element Definitions if submitting registration or results information M, Dassau E Markova! User Experience design Approach for a Connected Digital Diabetes Management platform number of saved studies ( 100 ) unique...., Rhea Teng, and world-renowned experts to meet your unique needs a study not. Vivid study results information insulin Doses using the System for an additional 6 months long-term study of insulin. Pump Users: a Survey of the artificial pancreas System PWD who lean toward “ Tubeless ” delivery!